Stationary injection currents in the single crystal CVD diamond detector quality
Keywords:
cooled detectors, wide-gap semiconductor, the injection of carriers, Au, CVD technology, synthetic materials, ionizing radiationAbstract
The method of the current limited by space charge (steady current injection), investigated the structure of the synthetic single crystal CVD diamond that showed sensitivity to γ-radiation. When a bias voltage U < 250 V values of injection current is less than 1pA. Measured current characteristics of the structures shown stability over time. One of the structures under study can be recommended for use as a sensing element of the detector of ionizing radiation, including medical devices-clinical dosimeters.
References
Вечерин П.П., Журавлев В.В., Квасков В.Б. Природные алмазы России. М.: Полярон, 1999. 304 с.
Квасков В.Б. Алмаз в электронной технике. М.: Энергоатомиздат, 1990.
Козлов С.Ф. Алмазные детекторы ядерных излучений. М.: Энергоатомиздат, 1990. 126 с.
Ламперт М., Марк П. Инжекционные токи в твердых телах. М.: Мир, 1973.
Новикова Н.В. Физические свойства алмаза. Киев: Наукова думка, 1987. 20 с.
Пыхтунова А.И., Шарапежникова Н.И. Активные полупроводниковые приборы на основе алмаза. М.: ФГУП «НПП «Пульсар», 2007.
Galbiati et al. Performance of Monocrystalline Diamond Radiation Detectors Fabricated Using TiW, Cr/Au and a Novel Ohmic DLC/Pt/Au Electrical Contact // IEEE TNS. 2009. V. 56, N 4 (August)